21 research outputs found

    Enabling and understanding nanoparticle surface binding assays with interferometric imaging

    Get PDF
    There is great need of robust and high throughput techniques for accurately measuring the concentration of nanoparticles in a solution. Microarray imaging techniques using widely used to quantify the binding of labeled analytes to a functionalized surface. However, most approaches require the combined output of many individual binding events to produce a measurable signal, which limits the sensitivity of such assays at low sample concentrations. Although a number of high-NA optical techniques have demonstrated the capability of imaging individual nanoparticles, these approaches have not been adopted for diagnostics due complex instrumentation and low assay throughput. Alternatively, interferometric imaging techniques based on light scattering have demonstrated the potential for single nanoparticle detection on a robust and inexpensive platform. This dissertation focuses on the development of methods and infrastructure to enable the development of diagnostic assays using the Single Particle Interferometric Imaging Sensor (SP-IRIS). SP-IRIS uses a bright-field reflectance microscope to image microarrays immobilized on a simple reflective substrate, which acts as a common-path homodyne interferometer to enhance the visibility of nanoparticles captured near its surface. This technique can be used to detect natural nanoparticles (such as viruses and exosomes) as well as molecular analytes (proteins and nucleic acid sequences) which have been tagged with metallic nanoparticle in a sandwich assay format. Although previous research efforts have demonstrated the potential for SP-IRIS assays in a variety of applications, these studies have largely been focused on demonstrating theoretical proof of concept in a laboratory setting. In contrast, the effective use of SP-IRIS as a clinical diagnostic platform will require significant functional improvements in automation of assay incubation, instrument control, and image analysis. In this dissertation, we discuss the development of instrumentation and software to support the translation of SP-IRIS from manual laboratory technique into an automated diagnostic platform. We first present a collection of mechanical solutions to enable the real-time, in-solution imaging of nanoparticles in disposable microfluidic cartridges. Next, we present image analysis techniques for the detection of nanoparticle signatures within digital images, and discuss solutions to the unique obstacles presented by the ill-defined focal properties of homodyne interferometry. Finally, we present a particle tracking algorithm for residence time analysis of nanoparticle binding in real-time datasets. Collectively, these improvements represent significant progress towards the use of SP-IRIS as a robust and automated diagnostic platform.2019-07-02T00:00:00

    Beating the reaction limits of biosensor sensitivity with dynamic tracking of single binding events

    Full text link
    The clinical need for ultrasensitive molecular analysis has motivated the development of several endpoint-assay technologies capable of single-molecule readout. These endpoint assays are now primarily limited by the affinity and specificity of the molecular-recognition agents for the analyte of interest. In contrast, a kinetic assay with single-molecule readout could distinguish between low-abundance, high-affinity (specific analyte) and high-abundance, low-affinity (nonspecific background) binding by measuring the duration of individual binding events at equilibrium. Here, we describe such a kinetic assay, in which individual binding events are detected and monitored during sample incubation. This method uses plasmonic gold nanorods and interferometric reflectance imaging to detect thousands of individual binding events across a multiplex solid-phase sensor with a large area approaching that of leading bead-based endpoint-assay technologies. A dynamic tracking procedure is used to measure the duration of each event. From this, the total rates of binding and debinding as well as the distribution of binding-event durations are determined. We observe a limit of detection of 19 fM for a proof-of-concept synthetic DNA analyte in a 12-plex assay format.First author draf

    Robust visualization and discrimination of nanoparticles by interferometric imaging

    Full text link
    Single-molecule and single-nanoparticle biosensors are a growing frontier in diagnostics. Digital biosensors are those which enumerate all specifically immobilized biomolecules or biological nanoparticles, and thereby achieve limits of detection usually beyond the reach of ensemble measurements. Here we review modern optical techniques for single nanoparticle detection and describe the single-particle interferometric reflectance imaging sensor (SP-IRIS). We present challenges associated with reliably detecting faint nanoparticles with SP-IRIS, and describe image acquisition processes and software modifications to address them. Specifically, we describe a image acquisition processing method for the discrimination and accurate counting of nanoparticles that greatly reduces both the number of false positives and false negatives. These engineering improvements are critical steps in the translation of SP-IRIS towards applications in medical diagnostics.R01 AI096159 - NIAID NIH HHSFirst author draf

    Interferometric detection and enumeration of viral particles using Si-based microfluidics

    Full text link
    Single-particle interferometric reflectance imaging sensor enables optical visualization and characterization of individual nanoparticles without any labels. Using this technique, we have shown end-point and real-time detection of viral particles using laminate-based active and passive cartridge configurations. Here, we present a new concept for low-cost microfluidic integration of the sensor chips into compact cartridges through utilization of readily available silicon fabrication technologies. This new cartridge configuration will allow simultaneous detection of individual virus binding events on a 9-spot microarray, and provide the needed simplicity and robustness for routine real-time operation for discrete detection of viral particles in a multiplex format.This work was supported in part by a research contract with the ASELSAN Research Center, Ankara, Turkey, and in part by the European Union's Horizon 2020 FET Open program under Grant 766466-INDEX. (ASELSAN Research Center, Ankara, Turkey; 766466-INDEX - European Union's Horizon 2020 FET Open program)First author draf

    Reversal to air-driven sound production revealed by a molecular phylogeny of tongueless frogs, family Pipidae

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Evolutionary novelties often appear by conferring completely new functions to pre-existing structures or by innovating the mechanism through which a particular function is performed. Sound production plays a central role in the behavior of frogs, which use their calls to delimit territories and attract mates. Therefore, frogs have evolved complex vocal structures capable of producing a wide variety of advertising sounds. It is generally acknowledged that most frogs call by moving an air column from the lungs through the glottis with the remarkable exception of the family Pipidae, whose members share a highly specialized sound production mechanism independent of air movement.</p> <p>Results</p> <p>Here, we performed behavioral observations in the poorly known African pipid genus <it>Pseudhymenochirus </it>and document that the sound production in this aquatic frog is almost certainly air-driven. However, morphological comparisons revealed an indisputable pipid nature of <it>Pseudhymenochirus </it>larynx. To place this paradoxical pattern into an evolutionary framework, we reconstructed robust molecular phylogenies of pipids based on complete mitochondrial genomes and nine nuclear protein-coding genes that coincided in placing <it>Pseudhymenochirus </it>nested among other pipids.</p> <p>Conclusions</p> <p>We conclude that although <it>Pseudhymenochirus </it>probably has evolved a reversal to the ancestral non-pipid condition of air-driven sound production, the mechanism through which it occurs is an evolutionary innovation based on the derived larynx of pipids. This strengthens the idea that evolutionary solutions to functional problems often emerge based on previous structures, and for this reason, innovations largely depend on possibilities and constraints predefined by the particular history of each lineage.</p

    Real-Time Capture and Visualization of Individual Viruses in Complex Media

    No full text
    Label-free imaging of individual viruses and nanoparticles directly in complex solutions is important for virology research and biosensing applications. A successful visualization technique should be rapid, sensitive, and inexpensive, while needing minimal sample preparation or user expertise. Current approaches typically require fluorescent labeling or the use of an electron microscope, which are expensive and time-consuming to use. We have developed an imaging technique for real-time, sensitive, and label-free visualization of viruses and nanoparticles directly in complex solutions such as serum. By combining the advantages of a single-particle reflectance imaging sensor, with microfluidics, we perform real-time digital detection of individual 100 nm vesicular stomatitis viruses as they bind to an antibody microarray. Using this approach, we have shown capture and visualization of a recombinant vesicular stomatitis virus Ebola model (rVSV-ZEBOV) at 100 PFU/mL in undiluted fetal bovine serum in less than 30 min

    Real-Time Capture and Visualization of Individual Viruses in Complex Media

    No full text
    Label-free imaging of individual viruses and nanoparticles directly in complex solutions is important for virology research and biosensing applications. A successful visualization technique should be rapid, sensitive, and inexpensive, while needing minimal sample preparation or user expertise. Current approaches typically require fluorescent labeling or the use of an electron microscope, which are expensive and time-consuming to use. We have developed an imaging technique for real-time, sensitive, and label-free visualization of viruses and nanoparticles directly in complex solutions such as serum. By combining the advantages of a single-particle reflectance imaging sensor, with microfluidics, we perform real-time digital detection of individual 100 nm vesicular stomatitis viruses as they bind to an antibody microarray. Using this approach, we have shown capture and visualization of a recombinant vesicular stomatitis virus Ebola model (rVSV-ZEBOV) at 100 PFU/mL in undiluted fetal bovine serum in less than 30 min
    corecore